Introduction

Heatizon Systems is glad to offer product phone support for the Heatwave product. It is VERY important to have read this manual first. Please have your resistance test numbers and system model name/number available BEFORE calling for technical support.


DOWNLOAD PDF INSTALL MANUAL (COMPLETE)

The Heatwave® Heating Cable comes in pre-established lengths that have been designed to deliver a specified heat density. Therefore, it is essential that all of the Heatwave® Heating Element contained in the kit be installed. Do not cut or alter the red heating cable in any way.

In order to minimize the risk of damage to the Heatwave® Heating Cable, Heatizon Systems
recommends that the Heatwave® Cable be installed immediately prior to the installation of the cementitious material that goes over it.

Never cross the Heatwave® Heating Cable over itself, the in-floor sensor wire, or any other conductor or wire.

When installing Heatizon Systems products, strict compliance with the National Electrical Code, local Building Codes, and Heatizon’s Installation Manual is essential.

It is highly recommend to take photographs to document the installed Heatwave® for future
reference before installing the flooring.


Jump to a Section