Planning The Installation
Before laying the Heatwave® Cable or Mat Floor Warming System, review the installation layout and verify that all dimensions match the need of the project. The installation plan should include the following:
- Placement, direction, and dimensions of the Heatwave® Cable or Mat.
- The starting and ending points of each Heating Cable length or Mat size.
- The location of the thermostat or other suitable activation.
- The location of the floor sensor between two heating cables.
REMEMBER! The installation plan* for each area should be retained and be provided to the building owner when the installation is complete.
*It is recommended that photographs be taken to document the installation of the layout.
Installation Considerations
DO:
- Completely inspect the Heatwave® System immediately upon its arrival and report any damage to Heatizon Systems and the delivery party.
- Clean the floor of all debris before placing the mat/cable on the floor.
- Make sure there are no protruding objects (nails, staples, etc.) on the subfloor that could damage the heating element.
- Walk over the unprotected Cable/Mat with rubber soled shoes.
- Measure and record Cable/Mat resistance according to the instructions.
- Use Cables/Mats connected to the same controller or used in the same room or area, that have the same heat output. i.e. ALL Cables/Mats should be EITHER 10 watts/sq. ft. OR ALL 15 watts/sq. ft.
- Make sure all components of the system are rated for the same Voltage (120V OR 240V).
- Have all electrical work completed by a professional electrician in accordance with all local and national codes and regulations.
- Call our Technical Support Hot line at 888-239-1232, for answers to installation questions, help solving a problem, or believe that the Heatwave® system was cut or damaged during installation.
DON’T
- DON’T cut the red heating wire.
- DON’T POWER ON the Heatwave® system until COMPLETELY EMBEDDED in cementious material
- DON’T drop or bang any tools (i.e. trowel) on or hit the heating wires with any sharp objects.
- DON’T install any fasteners such as nails, screws, etc. through any area covered by the Heatwave® Cable/Mat.
- DON’T shorten the spacing in the Mat.
- DON’T install Heatwave® under cabinets, built-in appliances, etc. to avoid excessive heat from building up in those areas.
- DON’T install Cables/Mats over expansion joints.
- DON’T install Heatwave® in walls.
- DON’T overlap Cables/Mats or allow any wires to cross or touch each other.
- DON’T crimp the heating wire while customizing the mat
- DON’T place high/thick insulating objects over the heated area to avoid excessive build-up of heat in these areas.
- DON’T forget to install the floor sensor.
- DON’T attempt to repair cut or damaged heating wire without contacting Heatizon Systems first 888-239-1232.
- DON’T install the Heatwave® system within 6” of a wax toilet gasket.
Important Safeguards and Warnings
WARNING: Shock and fire hazard
- If the Heatwave® System is damaged or not installed properly, fire or shock could occur resulting in serious personal injuries or damage to property. Carefully follow the warnings and instructions contained in this manual.
- It is important that this equipment is installed only by qualified persons who are familiar with the proper sizing, installation, construction and operation of floor warming systems and the hazards involved.
- The installation must comply with all national and local electrical codes. Consult the authority in the jurisdiction familiar with these requirements, either the NEC (National Electric Code), CSA (Canadian Standard Association) should there be any questions.
- The Heatwave® System is designed for under floor heating purposes only. Be sure that the floor is not penetrated by nails, screws, or similar devices that can cause damage during and after installation or during subsequent or future floor work.
- If the Heatwave® System is damaged, it must be replaced or repaired. To repair or to splice any part of the system, use only Heatizon Heatwave® Repair Kit (part number HWRPKIT).