Product Selection – Mats

4.1 Heatwave® Mat Selection

Confirm that Heatwave® product is no larger than the heated area. Following the example from Figure 3, if the heated area is 74 ft2, select the 70 ft2 Heatwave® Heating Mat.

Heatwave® Mats, 12 Watts/Ft2, 120 VAC

Heatizon Part
Number
Manufacturer
Number
Total
Watts
Total
Ohms
Amp
Load
Watts/
Foot
Coverage
Area/Square
Foot
Watts/
Square
Foot
Mat
Length
Mat
Width
Cable
spacing
(O.C.)
14AWG
Cold Lead
Length
HW2012-100HW2012-10120120.01.02.731012.006.1′20”2.90″15′
HW2012-150HW2012-1518080.01.53.591512.009.1′20”3.81″15′
HW2012-200HW2012-2024060.02.03.132012.0012.2′20”3.33″15′
HW2012-250HW2012-2530048.02.52.632512.0015.2′20”2.79″15′
HW2012-300HW2012-3036040.03.02.553012.0018.3′20”2.71″15′
HW2012-350HW2012-3542034.33.53.473512.0021.3′20”3.69″15′
HW2012-400HW2012-4048030.04.03.124012.0024.4′20”3.31″15′
HW2012-500HW2012-5060024.05.03.205012.0030.5′20”3.40″15′
HW2012-600HW2012-6072020.06.03.406012.0036.6′20”3.61″15′
HW2012-700HW2012-7084017.17.02.937012.0042.7′20”3.11″15′
HW2012-800HW2012-8096015.08.02.658012.0048.8′20”2.82″15′
HW2012-900HW2012-90108013.39.03.369012.0054.9′20”3.56″15′
HW2012-1000HW2012-100120012.010.04.1510012.0061.0′20”4.44″15′

Heatwave® Mats, 12 Watts/Ft2, 240 VAC

Heatizon Part
Number
Manufacturer
Number
Total
Watts
Total
Ohms
Amp
Load
Watts/
Foot
Coverage
Area/Square
Foot
Watts/
Square
Foot
Mat
Length
Mat
Width
Cable
spacing
(O.C.)
14AWG
Cold Lead
Length
HW2012-400BHW2024-40480120.02.03.134012.0024.4′20”3.33″15′
HW2012-500BHW2024-5060096.02.52.635012.0030.5′20”2.79″15′
HW2012-600BHW2024-6072080.03.02.556012.0036.6′20”2.71″15′
HW2012-700BHW2024-7084068.63.52.397012.0042.7′20”2.54″15′
HW2012-800BHW2024-8096060.04.03.128012.0048.8′20”3.31″15′
HW2012-900BHW2024-90108053.34.52.599012.0054.9′20”2.75″15′
HW2012-1000BHW2024-100120048.05.03.2010012.0061.0′20”3.40″15′
HW2012-1100BHW2024-110132043.65.52.8611012.0067.1′20”3.03″15′
HW2012-1200BHW2024-120144040.06.03.4012012.0073.2′20”3.61″15′
HW2012-1450BHW2024-145174033.17.33.1414512.0088.4′20”3.33″15′
HW2012-1600BHW2024-160192030.08.02.6516012.0097.6′20”2.82″15′

Important: Tools and materials required
The following items may be required to install and test the floor heating system:

ScissorsTape measureWire strippers
ScrewdriverTin snipsUtility knife
Plastic Cable Clips or StrappingHot glue gunMultimeter

Before Laying the Heatwave® Mat or Cable
Note: Measure the resistance between each conductor and the shielding/ground wire. Both should read infinity. Always complete a Heatizon Systems “Resistance in OHMS Form” (see form in the back of this manual) out of the box, immediately following the installation of the Heatwave® Heating Cable/Mat, immediately prior to covering the Heatwave® Heating Cable/Mat, and again just prior to energizing the Heatwave® Heating Cable/Mat.


Jump to Section